China PMC131-A11F1A2K Ceramic Pressure Transmitter (0-2bar) - China Supplier
China PMC131-A11F1A2K Ceramic Pressure Transmitter (0-2bar) - China Supplier China PMC131-A11F1A2K Ceramic Pressure Transmitter (0-2bar) - China Supplier China PMC131-A11F1A2K Ceramic Pressure Transmitter (0-2bar) - China Supplier

PMC131-A11F1A2K Ceramic Pressure Transmitter (0-2bar)

Instruments & Meters/Pressure Instruments/Pressure Transmitters


Contact Info
  • Haigu Technology Building, Luozu Community, Shiyan Subdistrict, Bao'an District, Shenzhen City, 518055
  • 陈鹏
  • 13590455705
  • 961744193@qq.com

Germany E+H Endress+Hauser PMC131-A11F1A2K Ceramic Pressure Transmitter (0-2bar)

Product Description

Ceramic measuring element pressure sensor

Capable of measuring gauge pressure and absolute pressure

High reliability and overload resistance

Application

Suitable for measuring absolute pressure and gauge pressure of gases, steam and liquids.

Features and Advantages

· Ceramic measuring element ensures measurement safety

· Reliability

· High stability

· Easy installation

Measuring System

· CerabarT pressure sensor with 4...20mA output

· Power supply voltage: 11-30V, if using the power supply units RN221, NX9120 or NX9121 provided by E+H

Technical Data

General Information

Manufacturer: E+H/Endress+Hauser

Instrument Name: Pressure Transmitter

Model: PMC131-A11F1A2K

Application

Measure gauge pressure and absolute pressure of gases, steam and liquids

Operation and System Design

Measuring Principle: The measured pressure generates a small deformation on the ceramic diaphragm of the sensor, and the electrodes on the ceramic sensor measure the resulting change in capacitance proportional to the pressure.

Modularity: The pressure sensing element can be connected to the transmitter power supply via optional DIN43650 A/ISO4400 plug or cable gland.

Input

Measured Variables: Gauge pressure or absolute pressure

Measuring Range: Max. 40bar (see selection table)

Output

Output Signal: 4⋯20mA

Load: R(Ω) ≤ (U-11V)/0.02A

Accuracy

Reference Conditions: Complies with DIN IEC 770

Rise Time: 20ms (T time)

Measurement Deviation (including hysteresis and repeatability): 0.5% FS

Nominal Range Ambient Temperature Effect: Zero point signal change between -20⋯+85℃ (-4...+185°F), typical: 1.5%; Range change between -20⋯+85℃ (-4...+185°F), typical: 0.8%; (0.4bar⋯40bar), typical: 1.0% (0.1bar)

Long-term Stability: 0.15%/year

Pressure Transmitter PMC131-A11F1A2K

Electrical Connection:

A1 Plug connector ISO4400 M16, IP65 NEMA4X

Process Connection:

1 Thread ISO228 G1/2, 304

Sensor Seal:

F FKM Viton

Additional Options:

1 Basic type

Measuring Range; Sensor Overload Limit:

A2K 0...2bar/200kPa abs; 18bar/1.8MPa